For industrial RO plants
Best Industrial RO Plant Service in Dhaka
We install, repair, clean, and maintain industrial RO plants for garments factories, textile facilities, general factories, food-processing sites, hotels, and commercial buildings. Our technicians work across a wide range of LPH capacities.
During business hours, a technician targets arrival within 90 minutes after we confirm your request. We inspect the plant, prepare the required work scope, and send the quote to your authorised contact.
Arrival target after confirmation
90 minutesPlants we service
Industrial RO plants we service across Dhaka
Tell us what the RO plant supplies, its rated LPH capacity, and its current output. We'll prepare the visit around the plant room, operating schedule, and site access rules.
Garments and textile facilities
We record feed pressure, product flow, TDS, membrane condition, dosing, storage, and reject-water flow.
General factories
We inspect factory RO plants, pre-treatment vessels, membranes, pumps, controls, tanks, and pipework.
Food-processing sites
We service approved RO equipment around the site hygiene rules, operating schedule, and access conditions.
Hotels
We inspect central RO plants, storage tanks, transfer pumps, controls, and distribution conditions.
Commercial buildings
We check the plant room, storage, automatic operation, and recorded output conditions.
Multi-site operations
We coordinate approved RO plants across several factories, branches, hotels, or buildings.
Plant service scope
Industrial RO plant installation, repair, cleaning, and maintenance
We inspect the plant before defining the work. Your authorised contact receives the service scope and quote before paid work begins.
Industrial RO Plant Installation
We assess feed water, required output, space, drainage, power, storage, and operating needs before quoting.
Fault Diagnosis and Repair
We trace low output, high TDS, pressure loss, pump, dosing, control, leakage, and reject-flow faults.
Media and Membrane Replacement
We inspect media, micron filters, membranes, housings, seals, gauges, and fittings before replacement.
Membrane Cleaning and CIP
We review pressure, flow, TDS, fouling signs, and operating history before cleaning or CIP.
Plant Performance Testing
We record pressure, flow, TDS, leakage, automatic operation, storage, and reject-water observations.
Planned Maintenance
We schedule inspection, cleaning, testing, and approved replacement work under a written plan.
Components we check
We inspect each stage of the industrial RO plant
We check the components that affect pressure, recovery, product-water quality, storage, and automatic operation.
Pre-treatment equipment
- Sand filter
- Carbon filter
- Softener
- Media vessels
- Valves and pipework
Filtration and membranes
- Micron filters
- RO membranes
- Membrane housings
- Seals and fittings
- Pressure gauges and flow meters
Pumps and dosing
- Feed pump
- High-pressure pump
- Dosing pump
- Chemical tank and dosing line
- Pump controls and protection
Controls and storage
- Control panel
- Automatic start and stop
- Level controls
- Product-water storage tank
- Reject-water route
Before installation
We define the new RO plant around your site requirements
Share the feed-water test, required LPH output, operating hours, product-water use, available space, drainage, power supply, storage demand, and access route.
We inspect the proposed plant area before preparing the written scope.
- 01
Confirm required output and product-water use
- 02
Review the feed-water source and test results
- 03
Inspect space, drainage, power, and access
- 04
Define treatment stages, pumps, controls, and storage
- 05
Present the equipment scope, labour, and quote
- 06
Install, flush, test, and record the plant
Inspected before work
We find the cause before preparing the repair scope
We inspect the reported fault, operating pressure, feed condition, pre-treatment, membranes, pumps, dosing, controls, storage, and reject-water route.
- Rated LPH capacity and current product flow
- Feed pressure and high-pressure pump condition
- Sand, carbon, softener, and micron filtration
- Membrane pressure, flow, TDS, and fouling signs
- Dosing pump, chemical tank, and dosing line
- Control panel, level control, and automatic operation
- Product-water storage and transfer condition
- Leakage, fittings, valves, and reject-water route
Membrane condition
We check whether the RO membranes need cleaning or replacement
We review pressure, product flow, TDS, fouling signs, and operating history. The findings show whether cleaning, CIP, replacement, or another plant correction is required.
We inspect membrane condition before recommending CIP or replacement.Clear service boundary
Our scope covers industrial RO plants and their treatment stages
We service RO pre-treatment, membranes, pumps, dosing, controls, storage, and reject-water systems. ETP, STP, boiler-water, and validated laboratory or pharmaceutical water systems remain outside our scope.
Share the plant use when requesting the site visit.Authorised before work
Your authorised contact approves the plant scope and quote
We separate labour, equipment, replacement parts, media, membranes, chemicals, and planned work in the quote. Changes found during the work require another approval.
Plant work begins after the scope and cost receive approval.Recorded before we leave
Every completed plant visit receives a written service report
The report identifies the site, plant capacity, reported fault, findings, approved work, fitted items, cleaning work, and final readings.
One identifiable report for every completed RO plant visit.Tested before handover
We test the serviced RO plant under the available site conditions
Feed-water condition, power supply, drainage, chemical availability, storage demand, and site operation affect the final readings.
- Feed and operating pressure
- Product-water flow
- Product-water TDS
- Visible leakage
- Pump operation
- Dosing operation
- Control panel and automatic operation
- Storage and level controls
- Reject-water flow and route
- Filter, membrane, valve, and fitting condition
Multiple plants, one agreement
Put approved RO plants and locations under one AMC
One annual maintenance agreement can cover approved RO plants at several factories, branches, hotels, or commercial buildings. We add another plant after written approval.
- Approved plants and rated capacities
- Factory, branch, hotel, or building addresses
- Planned visits and covered checks
- Service history for each plant
- Authorised contact for each location
- New plants added after written approval
Industrial service coverage
Industrial RO plant service across Dhaka
We cover garments factories, textile facilities, general factories, food-processing sites, hotels, and commercial buildings across Dhaka and surrounding areas.
The 90-minute target applies during business hours after confirmation. Traffic, weather, distance, gate entry, safety induction, and plant-room access affect the actual time.
Request a plant visit
Request an industrial RO plant site visit
Send the address, business type, plant use, rated LPH capacity, feed-water source, operating hours, reported problem, and authorised contact. We'll confirm by phone or WhatsApp.
We also serve
Water purifier service for other sites
FAQ
Industrial RO plant service questions
Which industrial RO plants and sites do you service?+
We service industrial RO plants in garments factories, textile facilities, general factories, food-processing sites, hotels, and commercial buildings across Dhaka. Our team works across a wide range of LPH capacities. Share the rated capacity, process use, feed-water source, and plant condition before the visit.
Do you install new industrial RO plants?+
Yes. We install new industrial RO plants after a site assessment confirms feed-water quality, required output, available space, drainage, power supply, storage, and operating needs. We prepare the plant scope and quote first. Installation starts after your authorised contact approves the written proposal.
Do you provide membrane cleaning and CIP?+
Yes. We provide membrane cleaning and CIP when the membrane condition and plant design support the work. We inspect pressure, flow, TDS, fouling signs, and operating history first. Damaged or exhausted membranes need replacement instead of cleaning, subject to your approval.
Can a technician reach our industrial site within 90 minutes?+
Yes. During business hours, a technician targets arrival within 90 minutes after we confirm the request. Traffic, weather, distance, technician availability, factory entry, safety induction, and plant-room access affect the actual time. Share the complete address, gate instructions, and authorised contact when requesting the visit.
Do you service ETP, STP, boiler-water, or pharmaceutical water systems?+
No. Our scope covers industrial RO plants and their pre-treatment, membrane, pumping, dosing, control, storage, and reject-water systems. ETP, STP, boiler-water treatment, and validated laboratory or pharmaceutical water systems require different technical controls. These systems remain outside the WPSBD service scope.